The Leoch XP12-210 is a high-performance 12V 210Ah Valve Regulated Lead Acid (VRLA) Absorbed Glass Mat (AGM) battery engineered specifically for enterprise-level applications requiring reliable backup power. This maintenance-free battery delivers exceptional performance, long service life, and superior deep discharge recovery in large UPS systems, telecommunications infrastructure, and other critical power installations.

Buy Leoch XP12-210 from Critical Power Battery Solutions

  • Leoch Authorized Distributor
  • Application-Specific Consultation
  • Competitive Leoch Volume Discounts
  • Global Leoch Shipping Capabilities
  • Leoch Warranty Processing & Support
  • Leoch Bulk Order Fulfillment
  • Emergency Delivery Options
  • Sustainable Battery Disposal Services

Leoch XP12-210 Key Features & Benefits

  • High Rate Performance:
    Engineered to deliver high current output for demanding applications
  • Deep Discharge Recovery:
    Superior recovery from deep discharge conditions
  • Maintenance-Free Design:
    Sealed construction eliminates the need for water additions
  • Low Self-Discharge:
    Maintains capacity during storage periods
  • Vibration Resistant:
    Robust internal construction for enhanced durability
  • Wide Operating Temperature Range:
    Reliable performance in various environmental conditions
  • Safety Valve Design:
    Prevents excessive gas buildup while maintaining a sealed environment
  • Non-Hazardous:
    Classified as “non-spillable” for shipping purposes
  • Recyclable:
    99% recyclable at end of service life

Leoch XP12-210 Technical Specifications

Specification

  • Chemistry:
  • Design:
  • Nominal Voltage:
  • Capacity:
  • Design Life:
  • Internal Resistance:
  • Self-Discharge Rate:
  • Operating Temperature:
  • Float Voltage:
  • Cycle Use Voltage:
  • Max Charge Current:
  • Max Discharge Current:
  • Terminal Type:
  • Dimensions (L×W×H):
  • Weight:
  • Warranty:

Details

  • Valve Regulated Lead Acid (VRLA)
  • Absorbed Glass Mat (AGM)
  • 12V
  • 210Ah @ 10-hour rate to 1.80V per cell @ 77°F (25°C)
  • 10+ years in float service at 77°F (25°C)
  • Approx. 3.2 mΩ (fully charged @ 77°F/25°C)
  • <3% per month at 77°F (25°C)
  • -4°F to 122°F (-20°C to 50°C)
  • 13.6-13.8V @ 77°F (25°C)
  • 14.6-14.8V @ 77°F (25°C)
  • 63A
  • 2100A (5 sec)
  • M8 Threaded Insert
  • 20.87 × 8.27 × 9.45 inches (530 × 210 × 240 mm)
  • Approx. 136.7 lbs (62 kg)
  • 1-year full replacement

  • Chemistry:
  • Design:
  • Nominal Voltage:
  • Capacity:
  • Design Life:
  • Internal Resistance:
  • Self-Discharge Rate:
  • Operating Temperature:
  • Float Voltage:
  • Cycle Use Voltage:
  • Max Charge Current:
  • Max Discharge Current:
  • Terminal Type:
  • Dimensions (L×W×H):
  • Weight:
  • Warranty:

  • Valve Regulated Lead Acid (VRLA)
  • Absorbed Glass Mat (AGM)
  • 12V
  • 210Ah @ 10-hour rate to 1.80V per cell @ 77°F (25°C)
  • 10+ years in float service at 77°F (25°C)
  • Approx. 3.2 mΩ (fully charged @ 77°F/25°C)
  • <3% per month at 77°F (25°C)
  • -4°F to 122°F (-20°C to 50°C)
  • 13.6-13.8V @ 77°F (25°C)
  • 14.6-14.8V @ 77°F (25°C)
  • 63A
  • 2100A (5 sec)
  • M8 Threaded Insert
  • 20.87 × 8.27 × 9.45 inches (530 × 210 × 240 mm)
  • Approx. 136.7 lbs (62 kg)
  • 1-year full replacement

Leoch XP12-210 Applications

The Leoch XP12-210 is specifically designed for:

UPS battery replacement systems icon for uninterruptible power supply applications

Enterprise UPS Systems:

Large data centers, corporate infrastructure, extended runtime applications

Telecommunications:

Central offices, mobile switching centers, transmission stations

Emergency lighting icon for battery backup and life-safety power systems

Emergency Systems:

Large-scale fire alarm, security, emergency lighting systems

Renewable Energy:

Medium to large-scale solar and wind energy storage

Medical equipment icon for UPS battery backup and critical power systems

Medical Facilities:

Hospitals, imaging centers, critical care equipment

Industrial factory icon for battery backup and manufacturing power systems

Industrial Controls:

Large process automation, control systems

Cruise ship icon for marine battery backup and vessel power systems

Transportation:

Railway signaling, traffic control systems

Leoch XP12-210 Competitive Alternatives

When comparing energy storage solutions, the Leoch XP12-210 offers several advantages over competing products:

  • Leoch XP12-210 vs. EnerSys PowerSafe SBS 210F: Comparable performance at a more competitive price point
  • Leoch XP12-210 vs. C&D Technologies UPS12-210MR: Enhanced high-rate discharge capability
  • Leoch XP12-210 vs. CSB GPL12210: Superior deep discharge recovery and cycle life
  • Leoch XP12-210 vs. Yuasa NPL210-12: Better high-temperature performance and longer design life
Leoch XP12-210 210Ah UPS battery replacement for mid-range backup power applications

Access comprehensive technical information for the Leoch XP12-210:

Download

Product Brochure

Why Choose Critical Power Battery Solutions for Your Leoch XP12-210 Needs

As an authorized reseller of Leoch batteries, Critical Power Battery Solutions offers unmatched expertise and service for Leoch XP12-210 batteries:

  • Technical Expertise: Our team of battery specialists provides expert guidance for your specific application
  • Competitive Pricing: Direct distributor relationship ensures the best possible pricing
  • Worldwide Shipping: Fast, reliable delivery to any global location
  • Installation Support: Professional installation and commissioning services available
  • Warranty Administration: Streamlined warranty processing and support
  • Recycling Services: Environmentally responsible disposal of old batteries

Leoch XP12-210 Frequently Asked Questions

Leoch XP12-210 batteries feature a high-density paste formulation and robust internal grid structure specifically engineered for enterprise-level applications. This design provides exceptional high-rate discharge capability, delivering consistent power during outages with minimal voltage drop under heavy loads. The AGM technology ensures excellent recovery from deep discharge events, a common occurrence in extended power outages. For a detailed assessment of how XP12-210 batteries can benefit your specific enterprise UPS or telecom application, contact CPBS at 630-984-9718.

Leoch XP12-210 batteries are designed with a service life of 10+ years at 77°F (25°C) when properly maintained in float service. Actual service life may vary based on operating conditions, maintenance practices, and discharge cycles. The high-quality lead calcium alloy grids significantly reduce grid corrosion, the primary failure mechanism in VRLA batteries. For specific lifespan projections based on your application and environment, contact CPBS at 630-984-9718 for a personalized assessment from our battery experts.

Leoch XP12-210 batteries should be stored in a clean, cool, and dry environment at temperatures between 68°F and 77°F (20°C and 25°C). Due to their low self-discharge rate (<3% per month), they can be stored for up to 6 months without recharging. For longer storage periods, a refresh charge is recommended every 6 months. Always store batteries in an upright position and avoid direct sunlight or heat sources. For guidance on proper storage procedures for your specific situation, contact CPBS at 630-984-9718.

Yes, Leoch XP12-210 batteries can be installed in series to increase voltage or in parallel to increase capacity. For series connections, up to four batteries (48V) can be connected without special considerations. For parallel connections, up to four strings are recommended for optimal performance and balanced charging. When connecting multiple batteries, it’s essential to use batteries of the same model, age, and state of charge. For assistance designing an optimal battery configuration for your specific application, contact CPBS technical experts at 630-984-9718.

For optimal performance and longevity, Leoch XP12-210 batteries should be charged using temperature-compensated voltage settings. The recommended float voltage is 13.6-13.8V at 77°F (25°C), with a temperature compensation of -3mV/°C/cell. For cyclic applications, the recommended charging voltage is 14.6-14.8V at 77°F (25°C) with a maximum charging current of 63A. Proper charging parameters are critical for battery longevity; for assistance configuring your charging system, contact CPBS at 630-984-9718.

ISO 9001 Certified – Through Our Parent Company , ATS

Our operations are supported by ISO 9001-certified processes through Advanced Technical Services Inc.
(ATS), providing you with confidence in every order and continuous commitment to improvement.

Expert Battery Sizing When Precision Matters

Don't risk undersizing or overspending on your critical power system. Our battery sizing experts bring over four decades of experience to ensure your installation meets exact specifications for optimal performance and longevity.

Why Schedule a Battery Sizing Consultation:

Precision engineering icon for advanced battery systems and technical expertise
Precision Engineering

Get exact calculations based on your specific load requirements and runtime needs

Application-specific icon for customized battery solutions and expert sizing
Application-Specific Expertise

Benefit from specialized knowledge in telecom, data center, utility, and renewable energy applications

Cost optimization icon for battery replacement services and value engineering
Cost Optimization

Avoid unnecessary expenses from oversizing or costly downtime from undersizing

Compliance assurance icon for battery standards and regulatory requirements
Compliance Assurance

Ensure your battery system meets all relevant industry standards and regulations

Future-proofing icon for UPS battery solutions and technology advancement
Future-Proofing

Plan for growth with scalable solutions that accommodate your evolving power needs

Our battery sizing experts will analyze your critical load requirements, environmental conditions, and backup duration needs to recommend the perfect solution for your application.

DELIVERABLE – IEEE 485 Battery Sizing report as well as a detailed pricing quote.

Free Battery Sizing Consultation