Premium VRLA Battery for Mission-Critical Applications

Leoch XP12-100

Leoch XP12-100 100Ah UPS battery replacement featured for standard backup power applications

Product Overview

The Leoch XP12-100 is a high-performance 12V 100Ah Valve Regulated Lead Acid (VRLA) Absorbed Glass Mat (AGM) battery engineered specifically for critical power applications requiring reliable backup power. This maintenance-free battery delivers exceptional performance, long service life, and superior deep discharge recovery in UPS systems, telecommunications, emergency lighting, and other mission-critical installations.

Buy Leoch XP12-100 from Critical Power Battery Solutions

  • Leoch Authorized Distributor
  • Application-Specific Consultation
  • Competitive Leoch Volume Discounts
  • Global Leoch Shipping Capabilities
  • Leoch Warranty Processing & Support
  • Leoch Bulk Order Fulfillment
  • Emergency Delivery Options
  • Sustainable Battery Disposal Services

Leoch XP12-100 Key Features & Benefits

  • High Rate Performance:
    Engineered to deliver high current output for demanding applications
  • Deep Discharge Recovery:
    Superior recovery from deep discharge conditions
  • Maintenance-Free Design:
    Sealed construction eliminates the need for water additions
  • Low Self-Discharge:
    Maintains capacity during storage periods
  • Vibration Resistant:
    Robust internal construction for enhanced durability
  • Wide Operating Temperature Range:
    Reliable performance in various environmental conditions
  • Safety Valve Design:
    Prevents excessive gas buildup while maintaining a sealed environment
  • Non-Hazardous:
    Classified as “non-spillable” for shipping purposes
  • Recyclable:
    99% recyclable at end of service life

Leoch XP12-100 Technical Specifications

Specification

  • Chemistry:
  • Design:
  • Nominal Voltage:
  • Capacity:
  • Design Life:
  • Internal Resistance:
  • Self-Discharge Rate:
  • Operating Temperature:
  • Float Voltage:
  • Cycle Use Voltage:
  • Max Charge Current:
  • Max Discharge Current:
  • Terminal Type:
  • Dimensions (L×W×H):
  • Weight:
  • Warranty:

Details

  • Valve Regulated Lead Acid (VRLA):
  • Absorbed Glass Mat (AGM):
  • 12V:
  • 100Ah @ 10-hour rate to 1.80V per cell @ 77°F (25°C):
  • 10+ years in float service at 77°F (25°C):
  • Approx. 4.5 mΩ (fully charged @ 77°F/25°C):
  • <3% per month at 77°F (25°C):
  • -4°F to 122°F (-20°C to 50°C):
  • 13.6-13.8V @ 77°F (25°C):
  • 14.6-14.8V @ 77°F (25°C):
  • 30A:
  • 1000A (5 sec):
  • M8 Threaded Insert:
  • 12.99 × 6.77 × 8.46 inches (330 × 172 × 215 mm):
  • Approx. 66.14 lbs (30 kg):
  • 1-year full replacement:

  • Chemistry:
  • Design:
  • Nominal Voltage:
  • Capacity:
  • Design Life:
  • Internal Resistance:
  • Self-Discharge Rate:
  • Operating Temperature:
  • Float Voltage:
  • Cycle Use Voltage:
  • Max Charge Current:
  • Max Discharge Current:
  • Terminal Type:
  • Dimensions (L×W×H):
  • Weight:
  • Warranty:

  • Valve Regulated Lead Acid (VRLA):
  • Absorbed Glass Mat (AGM):
  • 12V:
  • 100Ah @ 10-hour rate to 1.80V per cell @ 77°F (25°C):
  • 10+ years in float service at 77°F (25°C):
  • Approx. 4.5 mΩ (fully charged @ 77°F/25°C):
  • <3% per month at 77°F (25°C):
  • -4°F to 122°F (-20°C to 50°C):
  • 13.6-13.8V @ 77°F (25°C):
  • 14.6-14.8V @ 77°F (25°C):
  • 30A:
  • 1000A (5 sec):
  • M8 Threaded Insert:
  • 12.99 × 6.77 × 8.46 inches (330 × 172 × 215 mm):
  • Approx. 66.14 lbs (30 kg):
  • 1-year full replacement:

Leoch XP12-100 Applications

The Leoch XP12-100 is specifically designed for:

UPS battery replacement systems icon for uninterruptible power supply applications

Uninterruptible Power Supply (UPS) Systems:

Data centers, network equipment, medical facilities

Telecommunications:

Wireless base stations, network cabinets, fiber nodes

Emergency lighting icon for battery backup and life-safety power systems

Emergency Lighting:

Commercial buildings, industrial facilities, public spaces

Security system icon for UPS battery backup and emergency power applications

Security Systems:

Alarm panels, access control, surveillance equipment

Renewable Energy:

Small to medium solar and wind energy storage

Medical equipment icon for UPS battery backup and critical power systems

Medical Equipment:

Backup power for critical medical devices

Marine applications icon for UPS battery and backup power systems

Marine Applications:

Starting, lighting, and ignition for boats and watercraft

Leoch XP12-100 Competitive Alternatives

When comparing energy storage solutions, the Leoch XP12-100 offers several advantages over competing products:

  • Leoch XP12-100 vs. EnerSys PowerSafe SBS 100F: Comparable performance at a more competitive price point
  • Leoch XP12-100 vs. C&D Technologies UPS12-100MR: Enhanced high-rate discharge capability
  • Leoch XP12-100 vs. CSB GPL12100: Superior deep discharge recovery and cycle life
  • Leoch XP12-100 vs. Yuasa NPL100-12: Better high-temperature performance and longer design life
Leoch XP12-100 100Ah UPS battery replacement featured for standard backup power applications

Access comprehensive technical information for the Leoch XP12-100:

Download

Product Brochure

Why Choose Critical Power Battery Solutions for Your Leoch XP12-100 Needs

As an authorized reseller of Leoch batteries, Critical Power Battery Solutions offers unmatched expertise and service for Leoch XP12-100 batteries:

  • Technical Expertise: Our team of battery specialists provides expert guidance for your specific application
  • Competitive Pricing: Direct distributor relationship ensures the best possible pricing
  • Worldwide Shipping: Fast, reliable delivery to any global location
  • Installation Support: Professional installation and commissioning services available
  • Warranty Administration: Streamlined warranty processing and support
  • Recycling Services: Environmentally responsible disposal of old batteries

Leoch XP12-100 Frequently Asked Questions

Leoch XP12-100 batteries feature a high-density paste formulation and robust internal grid structure specifically engineered for critical power applications. This design provides exceptional high-rate discharge capability, delivering consistent power during outages with minimal voltage drop under heavy loads. The AGM technology ensures excellent recovery from deep discharge events, a common occurrence in extended power outages. For a detailed assessment of how XP12-100 batteries can benefit your specific UPS or critical power application, contact CPBS at 630-984-9718.

Leoch XP12-100 batteries are designed with a service life of 10+ years at 77°F (25°C) when properly maintained in float service. Actual service life may vary based on operating conditions, maintenance practices, and discharge cycles. The high-quality lead calcium alloy grids significantly reduce grid corrosion, the primary failure mechanism in VRLA batteries. For specific lifespan projections based on your application and environment, contact CPBS at 630-984-9718 for a personalized assessment from our battery experts.

Leoch XP12-100 batteries should be stored in a clean, cool, and dry environment at temperatures between 68°F and 77°F (20°C and 25°C). Due to their low self-discharge rate (<3% per month), they can be stored for up to 6 months without recharging. For longer storage periods, a refresh charge is recommended every 6 months. Always store batteries in an upright position and avoid direct sunlight or heat sources. For guidance on proper storage procedures for your specific situation, contact CPBS at 630-984-9718.

Yes, Leoch XP12-100 batteries can be installed in series to increase voltage or in parallel to increase capacity. For series connections, up to four batteries (48V) can be connected without special considerations. For parallel connections, up to four strings are recommended for optimal performance and balanced charging. When connecting multiple batteries, it’s essential to use batteries of the same model, age, and state of charge. For assistance designing an optimal battery configuration for your specific application, contact CPBS technical experts at 630-984-9718.

For optimal performance and longevity, Leoch XP12-100 batteries should be charged using temperature-compensated voltage settings. The recommended float voltage is 13.6-13.8V at 77°F (25°C), with a temperature compensation of -3mV/°C/cell. For cyclic applications, the recommended charging voltage is 14.6-14.8V at 77°F (25°C) with a maximum charging current of 30A. Proper charging parameters are critical for battery longevity; for assistance configuring your charging system, contact CPBS at 630-984-9718.

ISO 9001 Certified – Through Our Parent Company , ATS

Our operations are supported by ISO 9001-certified processes through Advanced Technical Services Inc.
(ATS), providing you with confidence in every order and continuous commitment to improvement.

Expert Battery Sizing When Precision Matters

Don't risk undersizing or overspending on your critical power system. Our battery sizing experts bring over four decades of experience to ensure your installation meets exact specifications for optimal performance and longevity.

Why Schedule a Battery Sizing Consultation:

Precision engineering icon for advanced battery systems and technical expertise
Precision Engineering

Get exact calculations based on your specific load requirements and runtime needs

Application-specific icon for customized battery solutions and expert sizing
Application-Specific Expertise

Benefit from specialized knowledge in telecom, data center, utility, and renewable energy applications

Cost optimization icon for battery replacement services and value engineering
Cost Optimization

Avoid unnecessary expenses from oversizing or costly downtime from undersizing

Compliance assurance icon for battery standards and regulatory requirements
Compliance Assurance

Ensure your battery system meets all relevant industry standards and regulations

Future-proofing icon for UPS battery solutions and technology advancement
Future-Proofing

Plan for growth with scalable solutions that accommodate your evolving power needs

Our battery sizing experts will analyze your critical load requirements, environmental conditions, and backup duration needs to recommend the perfect solution for your application.

DELIVERABLE – IEEE 485 Battery Sizing report as well as a detailed pricing quote.

Free Battery Sizing Consultation