Premium VRLA Battery for Mission-Critical Applications

Leoch PLH150FT(A)

Leoch PLH150FTA 150Ah front terminal battery for telecommunications and data center applications

Product Overview

The Leoch PLH150FT(A) is a premium 12V 150Ah Pure Lead Front Terminal VRLA battery engineered specifically for critical applications requiring exceptional reliability and performance. This maintenance-free battery delivers superior high-rate discharge capability, extended service life, and excellent deep discharge recovery in telecommunications, data centers, network equipment, and other mission-critical installations.

Buy Leoch PLH150FT(A) from Critical Power Battery Solutions

  • Leoch Authorized Distributor
  • Application-Specific Consultation
  • Competitive Leoch Volume Discounts
  • Global Leoch Shipping Capabilities
  • Leoch Warranty Processing & Support
  • Leoch Bulk Order Fulfillment
  • Emergency Delivery Options
  • Sustainable Battery Disposal Services

Leoch PLH150FT(A) Key Features & Benefits

  • Pure Lead Technology:
    99.99% pure lead plates for superior performance and extended service life
  • Front Terminal Design:
    Simplified installation and maintenance in rack-mounted applications
  • Extended Service Life:
    15+ years design life, significantly longer than standard VRLA batteries
  • Superior Cycle Performance:
    Up to 1200 cycles at 50% depth of discharge
  • Wide Temperature Range:
    Exceptional performance from -40°F to 131°F (-40°C to 55°C)
  • Low Internal Resistance:
    Higher efficiency and reduced heat generation during discharge
  • Maintenance-Free Design:
    Sealed construction eliminates the need for water additions
  • Ultra-Low Self-Discharge:
    Maintains capacity during extended storage periods
  • Non-Hazardous:
    Classified as “non-spillable” for shipping purposes
  • Environmentally Friendly:
    99% recyclable at end of service life

Leoch PLH170FT(A) Technical Specifications

Specification

  • Chemistry:
  • Design:
  • Nominal Voltage:
  • Capacity:
  • Design Life:
  • Internal Resistance:
  • Self-Discharge Rate:
  • Operating Temperature:
  • Float Voltage:
  • Cycle Use Voltage:
  • Max Charge Current:
  • Max Discharge Current:
  • Terminal Type:
  • Dimensions (L×W×H):
  • Weight:
  • Warranty:

Details

  • Valve Regulated Lead Acid (VRLA)
  • Pure Lead AGM with Front Terminal Access
  • 12V
  • 150Ah @ 10-hour rate to 1.80V per cell @ 77°F (25°C)
  • 15+ years in float service at 77°F (25°C)
  • Approx. 3.5 mΩ (fully charged @ 77°F/25°C)
  • <1% per month at 77°F (25°C)
  • -40°F to 131°F (-40°C to 55°C)
  • 13.5-13.8V @ 77°F (25°C)
  • 14.4-14.7V @ 77°F (25°C)
  • 45A
  • 1500A (5 sec)
  • M8 Front Access Threaded Insert
  • 19.09 × 5.43 × 8.74 inches (485 × 138 × 222 mm)
  • Approx. 119.0 lbs (54 kg)
  • 3-year full replacement

  • Chemistry:
  • Design:
  • Nominal Voltage:
  • Capacity:
  • Design Life:
  • Internal Resistance:
  • Self-Discharge Rate:
  • Operating Temperature:
  • Float Voltage:
  • Cycle Use Voltage:
  • Max Charge Current:
  • Max Discharge Current:
  • Terminal Type:
  • Dimensions (L×W×H):
  • Weight:
  • Warranty:

  • Valve Regulated Lead Acid (VRLA)
  • Pure Lead AGM with Front Terminal Access
  • 12V
  • 150Ah @ 10-hour rate to 1.80V per cell @ 77°F (25°C)
  • 15+ years in float service at 77°F (25°C)
  • Approx. 3.5 mΩ (fully charged @ 77°F/25°C)
  • <1% per month at 77°F (25°C)
  • -40°F to 131°F (-40°C to 55°C)
  • 13.5-13.8V @ 77°F (25°C)
  • 14.4-14.7V @ 77°F (25°C)
  • 45A
  • 1500A (5 sec)
  • M8 Front Access Threaded Insert
  • 19.09 × 5.43 × 8.74 inches (485 × 138 × 222 mm)
  • Approx. 119.0 lbs (54 kg)
  • 3-year full replacement

Leoch PLH150FT(A) Applications

The Leoch PLH150FT(A) is specifically designed for:

Telecommunications:

Central offices, mobile switching centers, transmission stations

Data Centers:

Server racks, network infrastructure, edge computing installations

UPS battery replacement systems icon for uninterruptible power supply applications

UPS Systems:

Medium to large-sized uninterruptible power supplies

Emergency lighting icon for battery backup and life-safety power systems

Security Systems:

Large-scale access control, surveillance equipment, alarm systems

Medical equipment icon for UPS battery backup and critical power systems

Medical Equipment:

Diagnostic equipment, critical care systems

Industrial factory icon for battery backup and manufacturing power systems

Industrial Controls:

Process control systems, automation equipment

Renewable Energy:

Medium to large-scale solar and wind energy storage

Leoch PLH150FT(A) Competitive Alternatives

When comparing energy storage solutions, the Leoch PLH150FT(A) offers several advantages over competing products:

  • Leoch PLH150FT(A) vs. EnerSys PowerSafe SBS 150F: Comparable performance at a more competitive price point
  • Leoch PLH150FT(A) vs. C&D Technologies TEL12-150: Enhanced high-rate discharge capability
  • Leoch PLH150FT(A) vs. CSB TPL121500: Superior deep discharge recovery and cycle life
  • Leoch PLH150FT(A) vs. Yuasa FXH150-12: Better high-temperature performance and longer design life

Why Choose Critical Power Battery Solutions for Your Leoch PLH150FT(A) Needs

As an authorized reseller of Leoch batteries, Critical Power Battery Solutions offers unmatched expertise and service for Leoch PLH150FT(A) batteries:

  • Technical Expertise: Our team of battery specialists provides expert guidance for your specific application
  • Competitive Pricing: Direct distributor relationship ensures the best possible pricing
  • Worldwide Shipping: Fast, reliable delivery to any global location
  • Installation Support: Professional installation and commissioning services available
  • Warranty Administration:  Streamlined warranty processing and support
  • Recycling Services:  Environmentally responsible disposal of old batteries

Leoch PLH150FT(A) Frequently Asked Questions

Leoch PLH150FT(A) batteries are specifically engineered for data center environments with several key advantages: 1) The pure lead technology provides exceptional performance and longevity in elevated temperature environments common in data centers, 2) The front terminal design optimizes rack space utilization and simplifies maintenance in densely packed server rooms, 3) The low internal resistance ensures minimal voltage drop during high-rate discharge events typical during power outages, and 4) The extended service life of 15+ years reduces total cost of ownership and maintenance frequency in these critical facilities. For a detailed assessment of how PLH150FT(A) batteries can benefit your specific data center application, contact CPBS technical experts at 630-984-9718.

The pure lead technology in Leoch PLH150FT(A) batteries extends service life through several mechanisms: 1) The 99.99% pure lead plates are significantly more resistant to grid corrosion, the primary failure mechanism in VRLA batteries, 2) The absence of alloying elements eliminates the formation of harmful compounds that can accelerate aging, 3) The higher purity lead provides superior conductivity, reducing internal heat generation during charge and discharge cycles, and 4) The specialized plate design maintains structural integrity over extended periods. These factors combine to deliver a 15+ year design life, approximately 3 times longer than standard VRLA batteries. For specific lifespan projections based on your application and environment, contact CPBS at 630-984-9718.

For critical applications using Leoch PLH150FT(A) batteries, we recommend implementing comprehensive battery monitoring systems that track voltage, internal resistance, temperature, and string current. Systems like the Alber BDS-256XL, Eagle Eye PowerSight, or Canara Monitoring Solutions provide real-time data and predictive analytics to identify potential issues before they affect system performance. These monitoring systems can be integrated with building management systems (BMS) or network management systems (NMS) for centralized oversight. For assistance selecting and implementing the optimal monitoring solution for your PLH150FT(A) battery installation, contact CPBS at 630-984-9718.

Leoch PLH150FT(A) batteries are engineered to deliver reliable performance in elevated temperature environments. While the optimal operating temperature is 77°F (25°C), these batteries incorporate specialized thermal management features that help mitigate the accelerated aging typically associated with high temperatures. The pure lead technology provides superior resistance to grid corrosion at elevated temperatures, while the advanced separator system improves heat dissipation. At a constant operating temperature of 86°F (30°C), the PLH150FT(A) can maintain approximately 12+ years of service life, compared to 7-8 years for standard VRLA batteries. For specific guidance on high-temperature applications and cooling strategies, contact CPBS technical experts at 630-984-9718.

The optimal string configuration for Leoch PLH150FT(A) batteries depends on your specific voltage and capacity requirements. For 48V systems (common in telecom applications), a string of four PLH150FT(A) batteries in series is recommended. For higher capacity requirements, multiple strings can be connected in parallel. However, we recommend limiting parallel strings to a maximum of four to minimize imbalances between strings. When designing multi-string configurations, it’s essential to implement string isolation diodes or circuit breakers to prevent circulating currents and allow for individual string maintenance. For assistance designing the optimal configuration for your specific application, contact CPBS battery system design experts at 630-984-9718.

ISO 9001 Certified – Through Our Parent Company , ATS

Our operations are supported by ISO 9001-certified processes through Advanced Technical Services Inc.
(ATS), providing you with confidence in every order and continuous commitment to improvement.

Expert Battery Sizing When Precision Matters

Don't risk undersizing or overspending on your critical power system. Our battery sizing experts bring over four decades of experience to ensure your installation meets exact specifications for optimal performance and longevity.

Why Schedule a Battery Sizing Consultation:

Precision engineering icon for advanced battery systems and technical expertise
Precision Engineering

Get exact calculations based on your specific load requirements and runtime needs

Application-specific icon for customized battery solutions and expert sizing
Application-Specific Expertise

Benefit from specialized knowledge in telecom, data center, utility, and renewable energy applications

Cost optimization icon for battery replacement services and value engineering
Cost Optimization

Avoid unnecessary expenses from oversizing or costly downtime from undersizing

Compliance assurance icon for battery standards and regulatory requirements
Compliance Assurance

Ensure your battery system meets all relevant industry standards and regulations

Future-proofing icon for UPS battery solutions and technology advancement
Future-Proofing

Plan for growth with scalable solutions that accommodate your evolving power needs

Our battery sizing experts will analyze your critical load requirements, environmental conditions, and backup duration needs to recommend the perfect solution for your application.

DELIVERABLE – IEEE 485 Battery Sizing report as well as a detailed pricing quote.

Free Battery Sizing Consultation